Open Access

Table 7.

The main decay heat generators between 4.5 and 20 years cooling time based on the SKB Benchmark [15]. The percent number given each nuclide emphasizes the partial contribution of heat of only one specific nuclide to the total heat produced at a certain time after shutdown.

2c∼4.5 y ∼8.5 y
Decay time Decay time
134Cs 21% 137Cs/137mBa 29%
137Cs/137mBa 20% 90Sr/90Y 26%
90Sr/90Y 19% 244Cm 15%
106Ru/106Rh 11% 238Pu 12%
244Cm 10% 134Cs 8%
238Pu 7% 241Am 4%
144Ce/144Pr 6% 154Eu 3%
154Eu 2%
241Am 1%

∼10 y ∼13.5 y
Decay time Decay time
137Cs/137mBa 31% 137Cs/137mBa 29%
90Sr/90Y 29% 90Sr/90Y 26%
244Cm 13% 238Pu 18%
238Pu 11% 244Cm 13%
134Cs 5% 241Am 7%
241Am 5% 154Eu 2%
154Eu 2% 134Cs 1%
240Pu 1% 240Pu 0%

∼21.5 y
Decay time
137Cs/137mBa 32%
90Sr/90Y 29%
238Pu 14%
244Cm 12%
241Am 9%
240Pu 2%
154Eu 1%

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.