Open Access

This article has an erratum: [https://doi.org/10.1051/epjn/2026014]


Table 7.

Calculated 235U (in g/t) in the case of the pincell and assembly benchmarks. Only direct (named “All”) and ULC values are presented here, and other values can be found in Appendix B.

Quantity 235UBOC 235UEOC2 235UEOC3 235UEOC4 235UEOL
Pincell model

All 31005  ±  11 23408  ±  62 14302  ±  158 9032  ±  154 5841  ±  154
ULC 31005  ±  8 23415  ±  55 14310  ±  147 9038  ±  144 5894  ±  125

Assembly model

All 31007  ±  12 23291  ±  70 13812  ±  121 8326  ±  119 5122  ±  137
ULC 31004  ±  8 23285  ±  61 13811  ±  107 8321  ±  102 5125  ±  100