Open Access

This article has an erratum: [https://doi.org/10.1051/epjn/2026014]


Table B.5.

Calculated values for the pincell and assembly models for the 235U concentrations (during irradiation and cooling). Values with a  ±  sign are average ±σ, whereas values within solid brackets ([ ]) are 95%/95% tolerance limits. In bold are indicated the reference values.

235UEOL (g/t) 235U5823 (g/t) 235U7970 (g/t)
Pincell model

All [5566 − 6215] [5466 − 6214] [5468 − 6214]
All 5891  ±  134 5840  ±  154 5841  ±  154
ULC 5894  ±  125 5849  ±  147 5850  ±  147
U 5870  ±  134 5841  ±  139 5842  ±  139
L 5871  ±  165 5796  ±  180 5798  ±  180
C 5895  ±  118 5867  ±  139 5868  ±  139

Assembly model

All [4793 − 5451] [4795 − 5453] [4796 − 5454]
All 5122  ±  137 5124  ±  137 5125  ±  137
ULC 5125  ±  100 5127  ±  100 5128  ±  100
U 5120  ±  148 5122  ±  148 5123  ±  148
L 5083  ±  130 5085  ±  130 5086  ±  130
C 5161  ±  88 5164  ±  88 5165  ±  88

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.