Table A.1.
General information for assembly 0E2 – part 1.
| Generic data | Values | References |
|---|---|---|
| Reactor type | Westinghouse | [3] |
| 3 loop PWR | ||
| Reactor name | Ringhals 3 | [3], page 15/253, Table 3-2 |
| Reactor coolant system pressure | 155 bar | [3], page 226/253 |
| Number of assemblies in core | 157 | [3], page 226/253 |
| Centrum distance between | 21.50 cm | [3], page 226/253 |
| fuel assemblies | ||
| Active length | 3658 mm | [3], page 227/253 |
| Average temperature into core | 600 K | See note 1 |
| at full power | ||
| Average temperature in pellets | 900 K | See note 1 |
| at full power | ||
| Coolant density | 0.72 g/cm3 | [5], page 84/180 |
| Reactor power | 2775 MW | [3], page 226/253, see note 4 |