Table 16.

Measured and calculated decay heat value for the Ringhals-3 assembly 0E2.

Cooling time (days) 5823 6389 6390 7826 7837 7970
Measured DH (Watts) 587.9 ± 7.0 566.0 ± 6.9 567.7 ± 6.9 522.4 ± 6.6 525.6 ± 6.6 520.1 ± 6.6
Code 1 (Watts) 587.9 568.4 568.3 535.7 525.4 521.8
Code 2 590.7 571.6 571.5 528.9 528.6 525.0
Code 3 579.8 561.0 561.0 519.4 556.6 515.6
Code 4 591.1 572.1 572.1 529.9 529.9 526.2
Code 5 584.2 564.0 564.0 520.1 519.8 516.0
History 1
ANSI/ANS-5.1-2014 738.7 ± 22.2 716.4 716.4 671.2 670.9 667.2
DIN 25463 (2014) 573.1 ± 22.5 554.7 554.6 514.2 513.9 510.5
ISO 10645:2022 685.7 ± 20.6 662.5 662.4 610.9 610.5 606.1
RG2 3.54 Rev2 (2018) 625.9 602.6 602.6 553.7 553.4 549.4
History 2
ANSI/ANS-5.1-2014 685.9 ± 23.8 665.2 665.2 623.3 623.0 619.6
DIN 25463 (2014) 576.5 ± 22.8 557.9 557.8 517.0 516.7 513.2
ISO 10645:2022 635.8 ± 22.7 614.2 614.2 566.6 566.2 562.2
RG2 3.54 Rev2 (2018) 605.8 583.3 583.2 536.1 535.8 532.0