Open Access

Table 2

Comparison of average C/E–1 (in %) between different types of calculations for BM1-P, BM1-S and BM3. The uncertainties correspond to the standard deviation, or 1σ. “AC” designates actinides and “FP” fission products. The calculations with SNF 1.07 are performed with the e7.202 library.

BM1-P BM1-S
Code AC FP AC + FP AC FP AC + FP
CASMO5 2.03 (pin) +7 ± 12 +22 ± 54 +18 ± 46 −0 ± 24 +16 ± 35 +10 ± 32
CASMO5 2.03 (assembly) +2 ± 9 +21 ± 55 +15 ± 46 −0 ± 21 +15 ± 34 +8 ± 31
SNF 1.07 (full core) +4 ± 9 +21 ± 55 +15 ± 46 −1 ± 11 +17 ± 34 +10 ± 29

BM3
Code AC FP AC + FP

CASMO5 2.03 (assembly) −5 ± 6 −1 ± 3 −3 ± 6
SNF 1.07 (full core) −3 ± 5 −3 ± 5 −3 ± 5

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.