Table 5

Important input parameters for the ten modelled cases.

Case number VAvg (m/s) Tin (K) Tout (K) Qxy (W) Re range Pr range
8 3.16 854 868 Equation (8) 6160–9160 10.2–14.7
10 3.46 868 893 Equation (8) 7570–11,200 9–12.8
19 2.08 862 876 Equation (8) 4250–6300 9.7–14
29 4.23 858 877 Equation (8) 8570–12,700 9.7–14
30 3.61 850 864 Equation (8) 6840–10,200 10.5–15.2
40 4.26 972 990 Equation (8) 15,200–22,400 5–7.6
43 3.95 989 1007 Equation (8) 14,800–22,300 4.6–7.2
44 3.60 991 1012 Equation (8) 13,600–20,600 4.5–7.1
45 3.20 975 999 Equation (8) 11,600–17,200 4.8–7.5
46 2.65 985 1013 Equation (8) 9950–15,000 4.5–7.2