Table 1.
Operation conditions of the ORS.
Unit | Value | |
---|---|---|
Turbomachinery speed relative | % | |
to the cycle design point | 20 | |
Compressor inlet p | MPa | 12.2 |
Compressor outlet p | MPa | 12.5 |
Compressor inlet T | °C | 55 |
CHX inlet T (CO2) | °C | 56 |
CHX outlet T (CO2) | °C | 150 |
CHX inlet T (H2O) | °C | 282 |
CHX outlet T (H2O) | °C | 56 |
CHX thermal power relative | % | |
to cycle design point (10 MW) | 11.3 | |
Mass flow rate (CO2) | kg/s | 5.6 |
Mass flow rate (H2O) | kg/s | 0.45 |
Compressor efficiency | % | 69.0 |
Turbine efficiency | % | 71.4 |
Compressor power | kW | 4.8 |
Turbine power | kW | 6.2 |
Fan power (Tair = 45°C) | kW | 0.4 |
Total power | kW | 1.0 |