Table 1.
Tests conditions for SIRIO experimentation.tab1
LFR (SIRIOas it is) |
ADS |
PWR |
BWR |
PHWR |
|||||
---|---|---|---|---|---|---|---|---|---|
Proposal 1 | Proposal 2 | Proposal 1 | Proposal 2 | Proposal 1 | Proposal 2 | Proposal 1 | Proposal 2 | ||
Layout & components modifications required | None | Direct connection of the non-condensable tank to the HX upper header | Heat transfer surface of HX increased by a factor 1.82 | Heat transfer surface of HX increased by a factor 1.82 | Extra vessel on Steam line. 6″×5.86 m | None | Modification of the diameters of the most piping of the loop | ||
Gas Tank volume increased by a factor 1.2 | |||||||||
Operation parameters | |||||||||
Power (kW) | 55 | 28.3 | 3.25 | 55 | 55 | 55 | 110 | 30 | 55 |
Pressure primary circuit (bar) | 180 | 16.0 | 16.0 | 60 | 60 | 72.52 | 72.52 | 46 | 46 |
Pressure gas tank (bar) | 110 | 12 | 12 | 50 | 50 | 50 | 69 | 30 | 30 |
Water inventory (kg) | 38 | 38 | 50.7 | 38 | 38 | 57.1 | 57.1 | 38 | 38 |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.