Open Access

Table 5

Main scenario uncertainties − truncated normal law at ±3σ⋅

Scenario variables Uncertainty range at (±2σ) Nominal value Derivation (σ) Inf limit (−3σ) Sup limit (+3σ)
Initial reactor power ±5% 1500 MW 2.5 −7.5 7.5
Residual power ±20% Calculated decrease (neutronic results) 10 −30 30
Primary pumps inertia ±20% 8000 kg.m2 10 −30 30
% of primary flow rate; criterion for RBH rods triggering ±20% 45% 10 −30 30
Anti-reactivity of one RBH rod ±5% 722 pcm 2.5 −7.5 7.5
Fall duration of RBH rods fall ±20% 3 s 10 −30 30