19 transients selected for this SFR safety demonstration (SA: Severe Accident).

Family Description Situation category Scientific calculation tool
Loss of function supporting General slowdown of the primary pumps OS2 CATHARE2
General acceleration of the primary pumps OS2 CATHARE2
Seizure or shaft failure of one primary pump OS3 MATHYS
Connection failure between a primary pump and diagrid OS4 MATHYS
Unprotected general slowdown of the primary pumps PS MATHYS
Defect of sub-assembly cooling Partial blockage of a fissile sub-assembly OS3 MATHYS
Partial blockage of an absorbent sub-assembly OS3 MATHYS
Progressive melting of a sub-assembly owing to a blockage PS SIMMER (SA)
Defect of primary circuit cooling One or several secondary pump trips OS2 CATHARE2
Unintentional draining of secondary loops OS3 CATHARE2
Unintentional closure of isolation valve on secondary loops OS4 CATHARE2
Defect of secondary and tertiary circuits cooling Station BlackOut shorter than 2 h OS2 CATHARE2
Station BlackOut longer than 2 h OS3 CATHARE2
Generalized under-voltage shorter than 3 days OS4 MATHYS
Unprotected Station BlackOut shorter than 2 h OS4 MATHYS
Reactivity variation Unintentional rising of a control rod OS2 Multiphysic Tool
Unintentional drop of a control rod OS2 Multiphysic Tool
Unintentional automatic reactor shut-down OS2 MATHYS
Unintentional fast reactor shut-down OS2 MATHYS