Table 3
Resulting values of the HX.
Parameters | Value |
---|---|
Plate thickness | 2 mm |
Seperator thickness | 2 mm |
Seperator height | ∼1.3 m |
Fuel channel thickness | 2 mm |
Coolant channel thickness | 2–4 mm |
Collector diameter | 0.21 m |
Fuel outlet temperature | ∼675 °C |
Temperature drop in HX | ∼75 °C |
Coolant outlet temperature | ∼620 °C |
Minimum temperature at fuel channel | ∼620 °C |
HX dimension (H×L×W) | ∼2.0×1.5×0.7 m |
Pressure drop in fuel channel | ∼3 bar |
Pressure drop in coolant channel | ∼5 bar |
Total fuel volume in 16 HX (HX and Collectors) | ∼6 m3 |