DPP2 (PWR 3086 MWth → 1000 MWe + 1000 MWth at 80 °C): electricity and heat costs.

  SPP DPP2
Reference core thermal power (MWth) 2748 3086 (+12.3%)
Reference electric power generation capacity (MWe) 1000 1000
Reference process heat generation capacity (MWth at 80 °C) 1000
Specific construction cost ($ per installed kWe (electric power)) 4101.51 4175.451 (+1.8%)
Specific fuel cost ($ per produced MWeh (electric power)) 9.33 10.478 (+12.31%)
Specific O&M cost ($ per produced MWeh (electric power)) 14.74 15.647 (+6.15%)
Specific decommissioning cost ($ per installed kWe (electric power)) 820.30 835.090 (+1.8%)
Length of the construction period (years) 7 7
Economic lifetime of the plant (years) 60 60
  Average availability of the plant (%) 85 84 (−1 point)
Length of the decommissioning period (years) 5 5
Discount rate (%) 5 5
Minimal annual cash in required to have a positive NPV (million $) 433.378 450.979 (+17.601)
Cost of electricity (10−2 $ per kWeh) 5.816  
Cost of heat (10−2 $ per kWthh at 80 °C) 0.308
Cost of heat (DPP) to cost of electricity (SPP) 5.30%  