Open Access
Table 6
Sequence of small break loss of coolant accident.
Time | Event |
---|---|
0 s | Small break (10 mm diameter) on DVI line B |
188 s | Low PRZ level leads to CMTs injection, PPHX actuation and coolant pumps stop |
190 s | Reactor scram triggered by pumps low speed (90%) |
193 s | Low PRZ pressure actuates reactor protection signal which triggers secondary lines isolation |
194 s | Emergency condensers are connected to SGs |
5 min | Apparition of a vapour phase in vessel upper head. Bulk boiling occurs in the reactor vessel |
25 min | Flashing of water into steam in the CMTs |
47 min | Low CMT levels actuate ADS opening |
58 min | ADS final stage opening |
59 min | Break flow turns into vapour phase. Beginning of accumulators injection (finished 100 s later) |
1 h 4 min | Beginning of safety tanks injection |
2 h 47 min | End of simulation |