Sequence of large break loss of coolant accident (LOCA).
Time | Event |
---|---|
0 s | Double-ended guillotine break of cold leg A |
0.1 s | Chain reaction is stopped by lack of moderation |
3 s | Low PRZ pressure causes a reactor protection signal |
3.15 s | Steam line and feedwater line isolation |
4 s | Reactor scram |
4.5 s | Reactor vessel has lost all coolant |
5 s | Opening of CMT injection valves |
5.5 s | Accumulators injection starts |
6 s | Coolant pumps stop on their inertia |
9 s | Passive primary cooling actuation |
9.5 s | Emergency condensers (ECs) are connected to steam generators (SGs) |
45 s | Maximum clad surface temperature reached (725 °C) |
77 s | End of accumulators injection |
98 s | CMTs injection starts |
13 min | CMTs low level causes opening of the ADS 1st stage |
15 min | Opening of the ADS 2nd stage |
16 min | Core is flooded again by primary coolant |
43 min | Opening of the ADS final stage |
90 min | End of simulation |