Table 1.

Comparison of critical boron concentration between calculated results and measured data.

Case Measured critical boron concentration [ppm] Calculated critical boron concentration [ppm] Difference from measured value [ppm]
All rods out (ARO) 975 984 ± 0.4* 9
D in 902 923 ± 0.2 21
C, D in 810 826 ± 0.1 16
A, B, C, D in 686 688 ± 0.3 2
A, B, C, D, SE, SD, SC in 508 502 ± 0.2 −6

*The calculation uncertainty of 1 standard deviation is shown.