Open Access
Table 4.
Uncertainties at 2σ in the power measured by heat balance.
Parameters | Uncertainties (2σ %) |
||||
---|---|---|---|---|---|
High-power plateau |
Low-power plateau |
||||
Engineering | High-Fidelity | Engineering | High-Fidelity | ||
Flow Rate Measurement | Q | 0.6% | 0.6% | 0.6% | 0.6% |
Calorific Capacity | Cp | 0.2% | 0.2% | 0.2% | 0.2% |
Temperature difference | ΔT | 5.4% | 5.4% | 12.0% | 12.0% |
Thermal Leakage | TL | 0.8% | 0.8% | 0.8% | 0.8% |
Gamma Correction | C(γ) | 0.8% | 0% | 0.8% | 0% |
Neutron Correction | C(n) | 0.8% | 0% | 0.8% | 0% |
Avg LHGR | P | 5.6% | 5.5% | 12.1% | 12.1% |