Open Access

Table 5

Deterministic calculation schemes used to calculate the activation of secondary sodium in the neutron shielding.

Scheme Sodium mesh Angular order Shielding description Required memory1 Computation time2
1 6 cm S16 Heterogeneous 124 Gb 49 h / 40 CPU
2 8 cm S16 Heterogeneous 100 Gb 56 h / 32 CPU
3 20 cm S16 Heterogeneous 50 Gb 36 h / 32 CPU
4 20 cm S6 Heterogeneous 41 Gb 16 h / 40 CPU
5 20 cm S6 Homogeneous 20 Gb 11 h / 24 CPU

1 There is a dependency between the memory cost and the number of processors. Therefore, these costs are indicative.

2 The calculations are run on different machines. Therefore, the calculation times are indicative.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.