Open Access

Table 6

Main model parameters uncertainties (1/2) − truncated normal law at ±3σ (neutronic best estimate data issued from the ERANOS tool [37] and thermo mechanical (TM) data issued from GERMINALGERMINAL tool [38]).

Modeled variable Uncertainty range at ±2σ Nominal value Derivation (σ) Inf limit (−3σ) Sup limit (+3σ)
Neutronic feedback due to fuel axial thermal expansion ±25% List of neutronic data* 12.5 −37.5 37.5
Doppler neutronic feedback ±15% List of neutronic data* 7.5 −22.5 22.5
Sodium void/density neutronic feedback ±20% List of neutronic data* 10 −30 30
Pellet/clad heat transfer coefficient ±20% List of TM data* 10 −30 30
Clad conductivity ±5% 19.52 (W/m/°C) 0.50 18.02 21.02
Singular head loss at the bottom of each sub-assembly ±10% Depending on flow rate 5 −15 15
Singular head loss at the bottom of storage sub-assembly ±10% 8648 5 −15 15
Singular head loss at the bottom of sub-assembly in debugging positions ±10% 3095 5 −15 15

*For some data (neutronic or TM), one particular value is defined for one group of sub-assemblies and/or for one axial mesh.