Open Access

Table 7

DPP2 (PWR 3086 MWth → 1000 MWe + 1000 MWth at 80 °C): mechanical and thermal powers.

Component Power (MW)
Steam generators 3086.14
High pressure turbine 1 −169.159
High pressure turbine 2 −237.905
Low pressure turbine 1 −269.206
Low pressure turbine 2 −226.627
Low pressure turbine 3 −115.962
Condenser1 (Process) −1000
Condenser2 (Tertiary circuit) −1086.14
Low pressure pump 1.90001
High pressure pump 16.9604
Sum 1.31 × 10−12
Net power output −1000
Power conversion efficiency (%) 32.4029