Open Access
Table 5
DPP1 (PWR 2748 MWth → 877 MWe + 1000 MWth at 80 °C): mechanical and thermal powers.
Component | Power (MW) |
---|---|
Steam generators | 2747.99 |
High pressure turbine 1 | −150.624 |
High pressure turbine 2 | −211.837 |
Low pressure turbine 1 | −239.709 |
Low pressure turbine 2 | −201.796 |
Low pressure turbine 3 | −89.7732 |
Condenser1 (Process) | −1000 |
Condenser2 (Tertiary circuit) | −871.044 |
Low pressure pump | 1.69183 |
High pressure pump | 15.102 |
Sum | 1.25 × 10−13 |
Net power output | −876.946 |
Power conversion efficiency (%) | 31.9123 |