Open Access

Table 3

SPP (PWR 2748 MWth → 1000 MWe): mechanical and thermal powers.

Component Power (MW)
Steam generators 2747.99
High pressure turbine 1 −150.624
High pressure turbine 2 −211.837
Low pressure turbine 1 −239.709
Low pressure turbine 2 −201.796
Low pressure turbine 3 −212.827
Condenser1 (Process) 0
Condenser2 (Tertiary circuit) −1747.99
Low pressure pump 1.69183
High pressure pump 15.102
Sum −1.14 × 10−13
Net power output −1000
Power conversion efficiency (%) 36.3902