Open Access

Table 2

Reactor thermal hydraulics parameters.

Parameter Value
Rated core heat 2815 MWt
Heat generated in fuel 97.4%
Coolant system pressure 15.5 MPa
Coolant in let temperature 289.7 °C
Linear average power of fuel rod 17.75 kW/m
Coolant mass flux 5900 kg/s m2
Average coolant velocity along rods 4.97 m/s