The main results of the tests with level boiling down.

Test No. Supplied power,
kW
Water flowrate,
kg/s
Temperature of flood water,
°C
Heat flux density,
kW/m
Maximum temperature,
°C
Cooldown time,
s
5 40 0.04 60 0.12 730 1200
6 80 0.07 60 0.24 800 1000
7 160 0.12 67 0.48 700 300
8 230 0.13 64 0.70 750 500
9 320 0.56 64 0.96 700 330