Open Access

Table 5

The main results of the tests with top flooding.

Test No. Supplied power in %
from nominal heat transfer
Water flowrate,
kg/s
Temperature of poured water,
°C
Linear heat flux
per one fuel rod,
kW/m
Maximum temperature,
°C
Cooldown time,
s
1 2.55 1.10–0.9 88 0.46 610 400
2 2.7 1.10–0.9 80 0.61 700 600
3 2.95 1.1–0.9 87 0.67 650 500
4 3.1 1.0 75 0.70 870 Assembly was not cooled down

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.