Open Access

Table 1

Chronology of major events.

Event Time [s] – Experiment Time [s] – CATHARE 3D
Break valve open 0 0
Initiation of coastdown of primary coolant pumps 11.5 12
Initiation of HPI system in loop with PZR (loop-A) only 26 27
Initiation of core power decay 30 30
Initiation of ACC system in loop-A only 154 158
Core reflooding 182 176
Upper plenum filling 195 190
Primary coolant pumps stopped 261 262
Termination of ACC system in loop-A only 350 340